Page 1 - POWERCUT-1250 / 1500

449POWERCUT-1250 / 1500MAINTENANCETROUBLESHOOTINGSCHEMATIC DIAGRAMSREPLACEMENT PARTS

Page 2

458 c. To check if the output is shorted, measure the resistance by putting the ohmmeter leads across the output. Put the black lead to the

Page 3 - SECTION 4 MAINTENANCE

459F. High Frequency and Pilot Arc are on but Main Arc does not transfer.1. Make sure work clamp is connected to work material.2. Check the torch.

Page 4

460Figure 5.1 IGBT Gating Signal5.2 REFERENCE VOLTAGE CHECKSA. Control Board Assembly (PCB1) 1. LED’s LED- (D9) - Torch Switch LED- (D4)

Page 5

461 TORCH SWITCH OPEN CLOSE GAS SOLENOID VALVE PREFLOW FLOW SWITCH CLOSE FAULT OVERLOAD LIGHT

Page 6

462 PUSH RELEASE PUSH RELEASE TORCH SWITCH OPEN CLOSE GAS SOLENOID VALVE

Page 7

463SECTION 5 TROUBLESHOOTINGNOTE:Schematics and Wiring Diagrams on 279.4mm x 431.8mm (11” x 17”) paper are included inside the back cover of this man

Page 8

464SECTION 5 TROUBLESHOOTING

Page 9

465SECTION 5 TROUBLESHOOTING

Page 10 - SECTION 5 TROUBLESHOOTING

466SECTION 5 TROUBLESHOOTING

Page 11

467SECTION 6 REPLACEMENT PARTS6.1 GeneralAlways provide the serial number of the unit on which the parts will be used. The serial number is stamped

Page 13

468SECTION 6 REPLACEMENT PARTS

Page 14

469REVISION HISTORYOriginal release of this manual is 05/2003.1. Revision of 11/2003 changed panel views to show updated voltage switch.2. Revision of

Page 15

ESAB ABSE--695 81 LAXÅSWEDENPhone +46 584 81 000Fax +46 584 123 08www.esab.comESAB subsidiaries and representative officesEuropeAUSTRIAESAB Ges.m.b.HV

Page 16

451SECTION 4 MAINTENANCE4.0 GENERALIf this equipment does not operate properly, stop work immediately and investigate the cause of the malfunction.

Page 17

452SECTION 4 MAINTENANCEListed below are common cutting problems followed by the probable cause of each. If problems are de-termined to be caused by

Page 18

453SECTION 4 MAINTENANCEP/N 0558008966PART NUMBER QTY DESCRIPTION0558006151 2 IGBT DUAL 150A 600V38224 1 PCB IGBT DRIVER05S12020 4 SCREW SKT

Page 20

4555.0 TROUBLESHOOTINGELECTRIC SHOCK CAN KILL! Be sure that all primary power to the machine has been externally disconnected. Open the line (wall)

Page 21 - REVISION HISTORY

4565.1 TROUBLESHOOTING GUIDEA. Power Light does not come on.1. Visually inspect the machine for any damage.2. Check following: a. Check if th

Page 22 - 0558004232 04/2009

4572. Check transformer secondary voltages at the output diode modules. Refer to system sche-matic. Replace the transformer module if the correct sec