ESAB POWERCUT-1250 Guide de dépannage Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
462
PUSH RELEASE PUSH RELEASE
TORCH SWITCH
OPEN CLOSE
GAS SOLENOID VALVE
POSTFLOW
CLOSE OPEN
FLOW SWITCH
FAULT LIGHT
HF CIRCUIT
PILOT ARC
INVERTER
CUTTING ARC (CURRENT)
B. TRIGGER LOCK "LOCK" position (Manual Cutting Only with PT-32EH Torch)
ENERGIZE
NOTES:
1. When the torch switch is pushed during postow period, the postow time is reset, the preow time is canceled, and
the HF is energized immediately.
2. When the red fault light comes on, cutting operation should be stopped. The postow time starts from the moment the
torch switch is released.
3. FAULT light is on during second "turn-o" trigger only. This does not aect performance in any way.
PREFLOW
2 SEC.
20 SEC
Postow
SECTION 5 TROUBLESHOOTING
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20 21 22