ESAB MultiPower 460 Pulse Manuel d'instructions Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
34
SECTION 4
OPERATION
Jumper Plug Removed and Harness connected (as factory shipped)
Non-Synergic Mode - The pulse parameters are determined by the position of
the pulse selection switches, the MultiPower 460 Pulse TRIM knob and Wire
Feed Speed preset.
Figure 4-7 Jumper Plug Removed and Harness Connected
Jumper Plug Installed
Synergic Mode - Pulse circuitry is looking for a 1 volt per 100 inches per
minute signal to determine the pulse parameters requied to make the weld.
Figure 4-8 Jumper Plug Installed (Factory Shipped)